FERRAZ ATQR系列熔斷器
聲明:您必須遵守我們的協(xié)議,如果您下載了該資源行為將被視為對(duì)《電天下賬號(hào)管理規(guī)范》全部?jī)?nèi)容的認(rèn)可,本網(wǎng)站資源來(lái)自原創(chuàng),僅供用于學(xué)習(xí)和交流,請(qǐng)勿用于商業(yè)用途。如有侵權(quán)、不妥之處,請(qǐng)舉報(bào)本資源,我們將及時(shí)審核處理!
FERRAZ ATQR系列熔斷器
文本預(yù)覽
AMP-TRAP 2000?
ATQR
TIME DELAY / CLASS CC
TAKE CONTROL OF FAULT CURRENTS HEADED
FOR YOUR CONTROL TRANSFORMER
ATQR small-dimension fuses feature time delay
characteristics ideally suited for the high inrush
currents of control transformers, solenoids, and
similar inductive loads. The newest member of our
Amp-trap 2000?family of fuses - ATQR fuses
provide superior protection for the branch circuits
of electrical distribution systems.
Features/Benefits
(cid:1) Time delayfor control transformer inrush loads without
nuisance opening
(cid:1) Highly current limiting for low peak let-thru current
(cid:1) Rejection-style design prevents replacement errors
(when used with recommended fuse blocks)
(cid:1) High-visibility orange label ensures instant recognition,
and simplifies replacement
(cid:1) Metal-embossed date and catalog number
for traceability and lasting identification
(cid:1) Fiberglass body provides dimensional stability in harsh
industrial settings
(cid:1) High-grade silica filler ensures fast arc quenching and
high current limitation
HIGHLIGHTS: APPLICATIONS: Ratings Approvals
(cid:1) Time Delay (cid:1) Control Transformers (cid:1) AC:1/10 to 30A (cid:1) UL Listed to
600VAC, 200kA I.R. Standard 248-4
(cid:1) Best Choice for Small (cid:1) Solenoids
(cid:1) CSA Certified to
Transformer Protection (cid:1) Inductive Loads Standard C22.2
(cid:1) Most Current-Limiting (cid:1) Lighting, Heating & No. 248.4
General-purpose Loads
A 16AMP-TRAP 2000?
TIME DELAY / CLASS CC FUSES ATQR
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG A
RATING NUMBER RATING NUMBER RATING NUMBER RATING NUMBER
1/10 ATQR1/10 8/10 ATQR8/10 2-8/10 ATQR2-8/10 7-1/2 ATQR7-1/2
1/8 ATQR1/8 1 ATQR1 3 ATQR3 8 ATQR8
15/100 ATQR15/100 1-1/8 ATQR1-1/8 3-2/10 ATQR3-2/10 9 ATQR9
3/16 ATQR3/16 1-1/4 ATQR1-1/4 3-1/2 ATQR3-1/2 10 ATQR10
2/10 ATQR2/10 1-4/10 ATQR1-4/10 4 ATQR4 12 ATQR12
1/4 ATQR1/4 1-1/2 ATQR1-1/2 4-1/2 ATQR4-1/2 15 ATQR15
3/10 ATQR3/10 1-6/10 ATQR1-6/10 5 ATQR5 17-1/2 ATQR17-1/2
4/10 ATQR4/10 1-8/10 ATQR1-8/10 5-6/10 ATQR5-6/10 20 ATQR20
1/2 ATQR1/2 2 ATQR2 6 ATQR6 25 ATQR25
6/10 ATQR6/10 2-1/4 ATQR2-1/4 6-1/4 ATQR6-1/4 30 ATQR30
3/4 ATQR3/4 2-1/2 ATQR2-1/2 7 ATQR7
Recommended ATQR Class CC Primary Fuses For Dimensions
Single Phase Control Transformers
TRANS PRIMARY ATQR TRANS PRIMARY ATQR
VA VOLTS FLA AMPS VA VOLTS FLA AMPS
600 0.04 1/10 600 0.50 1-1/8
480 0.05 1/10 480 0.63 1-1/2
25 240 0.10 2/10 300 240 1.25 2-1/2
208 0.12 1/4 208 1.44 3
120 0.21 4/10 120 2.5 5*
600 0.08 1/4 600 0.83 1-1/2
480 0.10 1/4 480 1.04 2
50 240 0.21 4/10 500 240 2.08 4*
208 0.24 1/2 208 2.40 6*
120 0.42 6/10 120 4.17 10*
600 0.13 1/4 600 1.25 2-1/2 Recommended Fuse Blocks for Class CC Fuses
480 0.16 3/10 480 1.56 3
75 240 0.31 1/2 750 240 3.13 7*
Number ULTRASAFE“ Screw Pressure Plate Copper
208 0.36 3/4 208 3.61 8*
of Indicating with Double with Double Box
120 0.63 1 120 6.25 15*
600 0.17 3/10 600 1.67 3 Poles Fuse Quick Quick Connector
480 0.21 4/10 480 2.08 4* Holder Connects Connects
100 240 0.42 6/10 1000 240 4.16 10*
208 0.48 1 208 4.81 12* ADDER 30310R 30320R 30350R
120 0.83 1-1/2 120 8.33 20* 1 USCC1I 30311R 30321R 30351R
600 0.25 1/2 600 2.50 5*
2 USCC2I 30312R 30322R 30352R
480 0.31 1/2 480 3.13 7*
150 240 0.63 1 1500 240 6.25 10 3 USCC3I 30313R 30323R 30353R
208 0.72 1-1/2 208 7.21 20*
120 1.25 2-1/2 120 12.5 25*
600 0.33 1/2 600 3.33 8* Primary fuses-If primary FLA is less than 2 amps, fuse may be 300%
480 0.42 6/10 2000 480 4.17 10* max. (500% for motor control). If primary FLA exceeds 2 amps but is
200 240 0.83 1-1/2 240 8.33 20++* less than 9 amps, fuse may not exceed 167% of primary FLA unless
208 0.96 2 208 9.62 20++* secondary protection is used, when it may be increased to 250%. Fuse
120 1.67 3 600 5.00 12+* sizes shown are based on approx. 40 x FLA for .01 sec.
600 0.42 6/10 3000 480 6.25 15+*
480 0.52 1-1/8 240 12.5 30++*
250 240 1.04 2 5000 600 8.33 20++* * Secondary protection is required for these ratings.
208 1.2 3 480 10.4 25+* + Fuse will withstand 30 x FLA for .01 second
120 2.08 4* ++ Fuse will withstand 25 x FLA for .01 second
A 17AMP-TRAP 2000?
TIME DELAY / CLASS CC FUSES ATQR
A 18
tnerruC
urhT-teL
kaeP
suoenatnatsnI
.xaM
ATQR
TIME DELAY / CLASS CC
TAKE CONTROL OF FAULT CURRENTS HEADED
FOR YOUR CONTROL TRANSFORMER
ATQR small-dimension fuses feature time delay
characteristics ideally suited for the high inrush
currents of control transformers, solenoids, and
similar inductive loads. The newest member of our
Amp-trap 2000?family of fuses - ATQR fuses
provide superior protection for the branch circuits
of electrical distribution systems.
Features/Benefits
(cid:1) Time delayfor control transformer inrush loads without
nuisance opening
(cid:1) Highly current limiting for low peak let-thru current
(cid:1) Rejection-style design prevents replacement errors
(when used with recommended fuse blocks)
(cid:1) High-visibility orange label ensures instant recognition,
and simplifies replacement
(cid:1) Metal-embossed date and catalog number
for traceability and lasting identification
(cid:1) Fiberglass body provides dimensional stability in harsh
industrial settings
(cid:1) High-grade silica filler ensures fast arc quenching and
high current limitation
HIGHLIGHTS: APPLICATIONS: Ratings Approvals
(cid:1) Time Delay (cid:1) Control Transformers (cid:1) AC:1/10 to 30A (cid:1) UL Listed to
600VAC, 200kA I.R. Standard 248-4
(cid:1) Best Choice for Small (cid:1) Solenoids
(cid:1) CSA Certified to
Transformer Protection (cid:1) Inductive Loads Standard C22.2
(cid:1) Most Current-Limiting (cid:1) Lighting, Heating & No. 248.4
General-purpose Loads
A 16AMP-TRAP 2000?
TIME DELAY / CLASS CC FUSES ATQR
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG A
RATING NUMBER RATING NUMBER RATING NUMBER RATING NUMBER
1/10 ATQR1/10 8/10 ATQR8/10 2-8/10 ATQR2-8/10 7-1/2 ATQR7-1/2
1/8 ATQR1/8 1 ATQR1 3 ATQR3 8 ATQR8
15/100 ATQR15/100 1-1/8 ATQR1-1/8 3-2/10 ATQR3-2/10 9 ATQR9
3/16 ATQR3/16 1-1/4 ATQR1-1/4 3-1/2 ATQR3-1/2 10 ATQR10
2/10 ATQR2/10 1-4/10 ATQR1-4/10 4 ATQR4 12 ATQR12
1/4 ATQR1/4 1-1/2 ATQR1-1/2 4-1/2 ATQR4-1/2 15 ATQR15
3/10 ATQR3/10 1-6/10 ATQR1-6/10 5 ATQR5 17-1/2 ATQR17-1/2
4/10 ATQR4/10 1-8/10 ATQR1-8/10 5-6/10 ATQR5-6/10 20 ATQR20
1/2 ATQR1/2 2 ATQR2 6 ATQR6 25 ATQR25
6/10 ATQR6/10 2-1/4 ATQR2-1/4 6-1/4 ATQR6-1/4 30 ATQR30
3/4 ATQR3/4 2-1/2 ATQR2-1/2 7 ATQR7
Recommended ATQR Class CC Primary Fuses For Dimensions
Single Phase Control Transformers
TRANS PRIMARY ATQR TRANS PRIMARY ATQR
VA VOLTS FLA AMPS VA VOLTS FLA AMPS
600 0.04 1/10 600 0.50 1-1/8
480 0.05 1/10 480 0.63 1-1/2
25 240 0.10 2/10 300 240 1.25 2-1/2
208 0.12 1/4 208 1.44 3
120 0.21 4/10 120 2.5 5*
600 0.08 1/4 600 0.83 1-1/2
480 0.10 1/4 480 1.04 2
50 240 0.21 4/10 500 240 2.08 4*
208 0.24 1/2 208 2.40 6*
120 0.42 6/10 120 4.17 10*
600 0.13 1/4 600 1.25 2-1/2 Recommended Fuse Blocks for Class CC Fuses
480 0.16 3/10 480 1.56 3
75 240 0.31 1/2 750 240 3.13 7*
Number ULTRASAFE“ Screw Pressure Plate Copper
208 0.36 3/4 208 3.61 8*
of Indicating with Double with Double Box
120 0.63 1 120 6.25 15*
600 0.17 3/10 600 1.67 3 Poles Fuse Quick Quick Connector
480 0.21 4/10 480 2.08 4* Holder Connects Connects
100 240 0.42 6/10 1000 240 4.16 10*
208 0.48 1 208 4.81 12* ADDER 30310R 30320R 30350R
120 0.83 1-1/2 120 8.33 20* 1 USCC1I 30311R 30321R 30351R
600 0.25 1/2 600 2.50 5*
2 USCC2I 30312R 30322R 30352R
480 0.31 1/2 480 3.13 7*
150 240 0.63 1 1500 240 6.25 10 3 USCC3I 30313R 30323R 30353R
208 0.72 1-1/2 208 7.21 20*
120 1.25 2-1/2 120 12.5 25*
600 0.33 1/2 600 3.33 8* Primary fuses-If primary FLA is less than 2 amps, fuse may be 300%
480 0.42 6/10 2000 480 4.17 10* max. (500% for motor control). If primary FLA exceeds 2 amps but is
200 240 0.83 1-1/2 240 8.33 20++* less than 9 amps, fuse may not exceed 167% of primary FLA unless
208 0.96 2 208 9.62 20++* secondary protection is used, when it may be increased to 250%. Fuse
120 1.67 3 600 5.00 12+* sizes shown are based on approx. 40 x FLA for .01 sec.
600 0.42 6/10 3000 480 6.25 15+*
480 0.52 1-1/8 240 12.5 30++*
250 240 1.04 2 5000 600 8.33 20++* * Secondary protection is required for these ratings.
208 1.2 3 480 10.4 25+* + Fuse will withstand 30 x FLA for .01 second
120 2.08 4* ++ Fuse will withstand 25 x FLA for .01 second
A 17AMP-TRAP 2000?
TIME DELAY / CLASS CC FUSES ATQR
A 18
tnerruC
urhT-teL
kaeP
suoenatnatsnI
.xaM
AIGC
FERRAZ ATQR系列熔斷器是巴西FERRAZ公司推出的一款高級(jí)別、高質(zhì)量的限流型快速熔斷器產(chǎn)品線。該系列熔斷器專為電力電子應(yīng)用設(shè)計(jì),特別適用于開關(guān)模式電源(SMPS)、變頻器、太陽(yáng)能逆變器、電動(dòng)車充電設(shè)備以及其他需要快速過(guò)載保護(hù)和短路電流限制的場(chǎng)合。
ATQR系列熔斷器采用獨(dú)特的技術(shù)和材料,具有響應(yīng)速度快、溫升低、耐重合閘能力強(qiáng)以及長(zhǎng)壽命等特點(diǎn)。其快速熔斷特性能夠在短時(shí)間內(nèi)切斷電路,有效防止設(shè)備因過(guò)載或短路造成的損害,從而提高系統(tǒng)的穩(wěn)定性和可靠性。此外,該系列熔斷器還提供多種規(guī)格和參數(shù)可供選擇,以滿足不同電壓等級(jí)、電流容量及各種保護(hù)需求的應(yīng)用場(chǎng)景。總體來(lái)說(shuō),F(xiàn)ERRAZ ATQR系列熔斷器在電氣行業(yè)中因其出色的性能和廣泛的適應(yīng)性而受到廣泛認(rèn)可。
相關(guān)資源推薦