Publication#:890034-03-00
RediStart Solid State
Starter User Manual
3
Control
(MVRMX & MVRXE Models)
1500 to 7200VAC
The Leader In
Solid State Motor Control
Technology
December2006
MotorStarterCardSet: BIPC-450100-01-01
SoftwareVersion1: 810023-02-01
SoftwareVersion2: 810024-01-01
GateDriverCard: 300047-01rev.13
?2006BenshawInc.
Benshaw,Inc.retainstherighttochangespecificationsandillustrationsintext,withoutpriornotification.Thecontentsofthisdocumentmaynotbecopied
withouttheexplicitpermissionofBenshaw,Inc.Important Reader Notice
CongratulationsonthepurchaseofyournewBenshawRediStartMVRMX3SolidStateStarter.Thismanualcontainstheinformationtoinstall
andprogramtheMVRMX3SolidStateStarter.
ThismanualmaynotcoveralloftheapplicationsfortheRediStartMVRMX3. Also,itmaynotprovideinformationoneverypossible
contingencyconcerninginstallation,programming,operation,ormaintenancespecifictotheRediStartMVRMX3SeriesStarters.
Thecontentofthismanualwillnotmodifyanyprioragreement,commitmentorrelationshipbetweenthecustomerandBenshaw.Thesales
contractcontainstheentireobligationofBenshaw.Thewarrantyenclosedwithinthecontractbetweenthepartiesistheonlywarrantythat
Benshawwillrecognizeandanystatementscontainedhereindonotcreatenewwarrantiesormodifytheexistingwarrantyinanyway.
AnyelectricalormechanicalmodificationstoBenshawproductswithoutpriorwrittenconsentofBenshawwillvoidallwarrantiesandmayalso
voidcULlistingorothersafetycertifications,unauthorizedmodificationsmayalsoresultinproductdamageoperationmalfunctionsorpersonal
injury.
Incorrecthandlingofthestartermayresultwithanunexpectedfaultordamagetothestarter.ForbestresultsonoperatingtheRediStartMX3
starter,carefullyreadthismanualandallwarninglabelsattachedtothestarterbeforeinstallationandoperation.Keepthismanualonhandfor
reference.
Donotattempttoinstall,operate,maintainorinspectthestarteruntilyouhavethoroughlyreadthismanualandrelateddocumentscarefully
andcanusetheequipmentcorrectly.
Donotusethestarteruntilyouhaveafullknowledgeoftheequipment,safetyproceduresandinstructions.
Thisinstructionmanualclassifiessafetyinstructionlevelsunder"WARNING"and"CAUTION".
ElectricalHazardthatcouldresultininjuryordeath.
Cautionthatcouldresultindamagetothestarter.
Highlightmarkinganimportantpointinthedocumentation.
Pleasefollowtheinstructionsofbothsafetylevelsastheyareimportanttopersonalsafety.
HighVoltage
Motorcontrolequipmentandelectroniccontrollersareconnectedtohazardouslinevoltages.Whenservicingstartersandelectronic
controllers,theremaybeexposedcomponentswithhousingsorprotrusionsatorabovelinepotential.Extremecareshouldbetaken
toprotectagainstshock.
Standonaninsulatingpadandmakeitahabittouseonlyonehandwhencheckingcomponents.Alwaysworkwithanotherperson
incaseanemergencyoccurs.Disconnectpowerbeforecheckingcontrollersorperformingmaintenance.Besureequipmentis
properlygrounded.Wearsafetyglasseswheneverworkingonelectroniccontrollersorrotatingmachinery.
TRADEMARKNOTICE
Benshawand areregisteredtrademarksofBenshawIncorporated.
ULisatrademarkofUnderwritersLaboratories,Incorporated.SAFETY PRECAUTIONS
SafetyPrecautions
ElectricShockPrevention
? Whilepowerisonorsoftstarterisrunning,donotopenthefrontcover.Youmaygetanelectricalshock.
(cid:129) Thissoftstartercontainshighvoltagewhichcancauseelectricshockresultinginpersonalinjuryorlossoflife.
(cid:129) BesureallACpowerisremovedfromthesoftstarterbeforeservicing.
(cid:129) Donotconnectordisconnectthewirestoorfromsoftstarterwhenpowerisapplied.
(cid:129) Makesuregroundconnectionisinplace.
(cid:129) Alwaysinstallthesoftstarterbeforewiring.Otherwise,youmaygetanelectricalshockorbeinjured.
(cid:129) Operatetheswitcheswithdryhandstopreventanelectricalshock.
(cid:129) RiskofElectricShock-Morethanonedisconnectswitchmayberequiredtode-energizetheequipmentbeforeservicing.
InjuryPrevention
(cid:129) Serviceonlybyqualifiedpersonnel.
(cid:129) Makesurepower-uprestartisofftopreventanyunexpectedoperationofthemotor.
(cid:129) Makecertainpropershieldinstallationisinplace.
(cid:129) Applyonlythevoltagethatisspecifiedinthismanualtotheterminalstopreventdamage.
TransportationandInstallation
(cid:129) Useproperliftinggearwhencarryingproducts,topreventinjury.
(cid:129) Makecertainthattheinstallationpositionandmaterialscanwithstandtheweightofthesoftstarter.Refertotheinstallation
informationinthismanualforcorrectinstallation.
3
(cid:129) Ifpartsaremissing,orsoftstarterisdamaged,donotoperatetheRediStartMVRMX .
(cid:129) Donotstandorrestheavyobjectsonthesoftstarter,asdamagetothesoftstartermayresult.
(cid:129) Donotsubjectthesoftstartertoimpactordropping.
(cid:129) Makecertaintopreventscrews,wirefragments,conductivebodies,oilorotherflammablesubstancesfromenteringthesoft
starter.
TrialRun
(cid:129) Checkallparameters,andensurethattheapplicationwillnotbedamagedbyasuddenstart-up.
EmergencyStop
(cid:129) Topreventthemachineandequipmentfromhazardousconditionsifthesoftstarterfails,provideasafetybackupsuchasan
emergencybrake.
DisposingoftheRediStartMVRMX3
(cid:129) Neverdisposeofelectricalcomponentsviaincineration.Contactyourstateenvironmentalagencyfordetailsondisposalof
electricalcomponentsandpackaginginyourarea.
iTABLE OF CONTENTS
TableofContents
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 TECHNICALSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 GeneralInformation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 ElectricalRatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2.1 TerminalPointsandFunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2.2 MeasurementsandAccuracies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.3 ListofMotorProtectionFeatures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.4 SolidStateMotorOverload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2.5 CTRatios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.6 OptionalRTDModuleSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.7 OptionalZeroSequenceGroundFaultCT. . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 SampleRediStartMVRMX3Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.4 EnvironmentalConditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5 AltitudeDerating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.6 RealTimeClock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.7 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RediStart Solid State
Starter User Manual
3
Control
(MVRMX & MVRXE Models)
1500 to 7200VAC
The Leader In
Solid State Motor Control
Technology
December2006
MotorStarterCardSet: BIPC-450100-01-01
SoftwareVersion1: 810023-02-01
SoftwareVersion2: 810024-01-01
GateDriverCard: 300047-01rev.13
?2006BenshawInc.
Benshaw,Inc.retainstherighttochangespecificationsandillustrationsintext,withoutpriornotification.Thecontentsofthisdocumentmaynotbecopied
withouttheexplicitpermissionofBenshaw,Inc.Important Reader Notice
CongratulationsonthepurchaseofyournewBenshawRediStartMVRMX3SolidStateStarter.Thismanualcontainstheinformationtoinstall
andprogramtheMVRMX3SolidStateStarter.
ThismanualmaynotcoveralloftheapplicationsfortheRediStartMVRMX3. Also,itmaynotprovideinformationoneverypossible
contingencyconcerninginstallation,programming,operation,ormaintenancespecifictotheRediStartMVRMX3SeriesStarters.
Thecontentofthismanualwillnotmodifyanyprioragreement,commitmentorrelationshipbetweenthecustomerandBenshaw.Thesales
contractcontainstheentireobligationofBenshaw.Thewarrantyenclosedwithinthecontractbetweenthepartiesistheonlywarrantythat
Benshawwillrecognizeandanystatementscontainedhereindonotcreatenewwarrantiesormodifytheexistingwarrantyinanyway.
AnyelectricalormechanicalmodificationstoBenshawproductswithoutpriorwrittenconsentofBenshawwillvoidallwarrantiesandmayalso
voidcULlistingorothersafetycertifications,unauthorizedmodificationsmayalsoresultinproductdamageoperationmalfunctionsorpersonal
injury.
Incorrecthandlingofthestartermayresultwithanunexpectedfaultordamagetothestarter.ForbestresultsonoperatingtheRediStartMX3
starter,carefullyreadthismanualandallwarninglabelsattachedtothestarterbeforeinstallationandoperation.Keepthismanualonhandfor
reference.
Donotattempttoinstall,operate,maintainorinspectthestarteruntilyouhavethoroughlyreadthismanualandrelateddocumentscarefully
andcanusetheequipmentcorrectly.
Donotusethestarteruntilyouhaveafullknowledgeoftheequipment,safetyproceduresandinstructions.
Thisinstructionmanualclassifiessafetyinstructionlevelsunder"WARNING"and"CAUTION".
ElectricalHazardthatcouldresultininjuryordeath.
Cautionthatcouldresultindamagetothestarter.
Highlightmarkinganimportantpointinthedocumentation.
Pleasefollowtheinstructionsofbothsafetylevelsastheyareimportanttopersonalsafety.
HighVoltage
Motorcontrolequipmentandelectroniccontrollersareconnectedtohazardouslinevoltages.Whenservicingstartersandelectronic
controllers,theremaybeexposedcomponentswithhousingsorprotrusionsatorabovelinepotential.Extremecareshouldbetaken
toprotectagainstshock.
Standonaninsulatingpadandmakeitahabittouseonlyonehandwhencheckingcomponents.Alwaysworkwithanotherperson
incaseanemergencyoccurs.Disconnectpowerbeforecheckingcontrollersorperformingmaintenance.Besureequipmentis
properlygrounded.Wearsafetyglasseswheneverworkingonelectroniccontrollersorrotatingmachinery.
TRADEMARKNOTICE
Benshawand areregisteredtrademarksofBenshawIncorporated.
ULisatrademarkofUnderwritersLaboratories,Incorporated.SAFETY PRECAUTIONS
SafetyPrecautions
ElectricShockPrevention
? Whilepowerisonorsoftstarterisrunning,donotopenthefrontcover.Youmaygetanelectricalshock.
(cid:129) Thissoftstartercontainshighvoltagewhichcancauseelectricshockresultinginpersonalinjuryorlossoflife.
(cid:129) BesureallACpowerisremovedfromthesoftstarterbeforeservicing.
(cid:129) Donotconnectordisconnectthewirestoorfromsoftstarterwhenpowerisapplied.
(cid:129) Makesuregroundconnectionisinplace.
(cid:129) Alwaysinstallthesoftstarterbeforewiring.Otherwise,youmaygetanelectricalshockorbeinjured.
(cid:129) Operatetheswitcheswithdryhandstopreventanelectricalshock.
(cid:129) RiskofElectricShock-Morethanonedisconnectswitchmayberequiredtode-energizetheequipmentbeforeservicing.
InjuryPrevention
(cid:129) Serviceonlybyqualifiedpersonnel.
(cid:129) Makesurepower-uprestartisofftopreventanyunexpectedoperationofthemotor.
(cid:129) Makecertainpropershieldinstallationisinplace.
(cid:129) Applyonlythevoltagethatisspecifiedinthismanualtotheterminalstopreventdamage.
TransportationandInstallation
(cid:129) Useproperliftinggearwhencarryingproducts,topreventinjury.
(cid:129) Makecertainthattheinstallationpositionandmaterialscanwithstandtheweightofthesoftstarter.Refertotheinstallation
informationinthismanualforcorrectinstallation.
3
(cid:129) Ifpartsaremissing,orsoftstarterisdamaged,donotoperatetheRediStartMVRMX .
(cid:129) Donotstandorrestheavyobjectsonthesoftstarter,asdamagetothesoftstartermayresult.
(cid:129) Donotsubjectthesoftstartertoimpactordropping.
(cid:129) Makecertaintopreventscrews,wirefragments,conductivebodies,oilorotherflammablesubstancesfromenteringthesoft
starter.
TrialRun
(cid:129) Checkallparameters,andensurethattheapplicationwillnotbedamagedbyasuddenstart-up.
EmergencyStop
(cid:129) Topreventthemachineandequipmentfromhazardousconditionsifthesoftstarterfails,provideasafetybackupsuchasan
emergencybrake.
DisposingoftheRediStartMVRMX3
(cid:129) Neverdisposeofelectricalcomponentsviaincineration.Contactyourstateenvironmentalagencyfordetailsondisposalof
electricalcomponentsandpackaginginyourarea.
iTABLE OF CONTENTS
TableofContents
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 TECHNICALSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 GeneralInformation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 ElectricalRatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2.1 TerminalPointsandFunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2.2 MeasurementsandAccuracies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.3 ListofMotorProtectionFeatures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.4 SolidStateMotorOverload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2.5 CTRatios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.6 OptionalRTDModuleSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.7 OptionalZeroSequenceGroundFaultCT. . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 SampleRediStartMVRMX3Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.4 EnvironmentalConditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5 AltitudeDerating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.6 RealTimeClock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.7 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
AIGC
尊敬的用戶(hù),本秀高壓軟啟動(dòng)器是一種專(zhuān)為工業(yè)環(huán)境中設(shè)計(jì)的電力電子設(shè)備,用于在電機(jī)啟動(dòng)時(shí)平滑地調(diào)節(jié)電壓和電流,從而減少電動(dòng)機(jī)起動(dòng)電流對(duì)電網(wǎng)的沖擊,延長(zhǎng)電動(dòng)機(jī)壽命并降低機(jī)械磨損。高壓軟啟動(dòng)器特別適用于高壓(通常指400V以上)交流異步電動(dòng)機(jī)的啟動(dòng)控制。
您所查詢(xún)的"本秀高壓軟啟動(dòng)器說(shuō)明書(shū)(英文版)",應(yīng)該是該產(chǎn)品的詳細(xì)技術(shù)文檔,內(nèi)容包括但不限于產(chǎn)品結(jié)構(gòu)、工作原理、安裝步驟、接線(xiàn)圖、參數(shù)設(shè)置、操作指南、故障排除以及安全注意事項(xiàng)等內(nèi)容,全部以英文編寫(xiě),以便國(guó)際化的使用和維護(hù)人員理解和參考。如果您需要獲取這份說(shuō)明書(shū),請(qǐng)?zhí)峁┚唧w的產(chǎn)品型號(hào)或者聯(lián)系本秀公司的官方支持服務(wù)獲取最準(zhǔn)確的信息。
相关资源推荐