ME320L電梯專用變頻器用戶手冊(cè)(英文)
聲明:您必須遵守我們的協(xié)議,如果您下載了該資源行為將被視為對(duì)《電天下賬號(hào)管理規(guī)范》全部?jī)?nèi)容的認(rèn)可,本網(wǎng)站資源來自原創(chuàng),僅供用于學(xué)習(xí)和交流,請(qǐng)勿用于商業(yè)用途。如有侵權(quán)、不妥之處,請(qǐng)舉報(bào)本資源,我們將及時(shí)審核處理!
ME320L電梯專用變頻器用戶手冊(cè)(英文)
文本預(yù)覽
ME320L(N)Elevator Specialized Inverter User Manual Preface
Preface
Thanks for using the products of Suzhou Monarch Control Technology Co.,
Ltd.ME320L(N)is a new generation of elevator specialized vector control
inverter, which is under the research and development of Suzhou Monarch
Control Technology Co., Ltd. It’s the result of many years’ experience in
elevator area, motor vector control and advanced algorithms like smooth curve
calculation, It’s the most practical, professional and easiest to use specialized
inverter! Its main features are as follows:
● Applies to the driving control of permanent-magnet synchronous motor
and asynchronous motor, possessing different kinds of rotary encoder
interfaces;
● Self-tuning function of motor parameters, including static tuning and full
tuning;
● Quick startup of curve processing, multi-stage S curve settings and
4-stage acceleration and deceleration time settings ensure the sense of
comfort during the running of the elevator;
● Simple and practical battery running function, the input of 48V power
supply can complete self-help when power is off;
● Enable inspection、brake contactor control, output contactor control,
forced deceleration judgment, over speed testing, speed deviation testing,
advanced door open, contact conglutination testing, motor overheat
testing, startup pre-torque compensation and other elevator special
functions make elevator control easier;
● The unique one-button design on the operation panel make complicated
keyboard operation easy; that it can be put anywhere through RJ45
terminal make elevator adjustment convenient and simple; parameter
copy unit make batch adjustment easy;
● Built-in DC reactor and braking unit improve output power factor of the
system and reduce the cost of outside components of the electrical
system;
● The whole series of independent duct design, professional lightning
protection design, professional manufacture platform and advanced
processs control ensure the quality of ME320L(N) specialized inverter;
● Please read and master this operating instruction, which is the attachmentPreface ME320L(N)Elevator Specialized InverterUser Manual
of the inverter, before using ME320L(N) inverter, and keep the instruction
well after reading.
The content of the manual has been conformed before print. However, our
company is devoted to perfecting and improving the products, so we keep the
right of revising product specifications, performance and other parts of the
manual. Sorry for no special notification if there’re any changes.
Suzhou Monarch Control Technology Co., Ltd provides all-round technical
support for customers. If there’re any questions, please contact Product Sales
Center or Customer Service Center of Monarch.Contents
PREFACE........................................................................................................1
CHAPTER 1 SAFETY INFORMATION AND NOTES.................................- 1 -
1.1 Safety Items..................................................................................................................................- 1 -
CHAPTER 2 PRODUCT INFORMATION...............................................- 9 -
2.1 Naming rules................................................................................................................................- 9 -
2.2 Nameplate.....................................................................................................................................- 9 -
2.3 Main models of ME320L(N) inverters(Including IP model)......................................- 10 -
2.4 Technical Specification...........................................................................................................- 10 -
2.5 Product figure and stallation hole size (IP model included)..................................- 12 -
2.6 Options(IP model included)..............................................................................................- 15 -
2.7 Daily maintenance of inverter...............................................................................................- 15 -
CHAPTER 3 INSTALLATION AND WIRING.............................................- 21 -
3.1 Mechanical Installation...........................................................................................................- 21 -
3.2 Electric Installation..................................................................................................................- 23 -
CHAPTER 4 OPERATION AND TEST-RUN OF THE INVERTER............- 41 -
4.1 Terms of ME320L(N) Inverter................................................................................................- 41 -
4.2 Introduction of operation and display panel.....................................................................- 42 -
4.3 Function codes examination and operation instruction...............................................- 43 -
4.4 Operation of shortcut menu..................................................................................................- 45 -
4.5 Password setting......................................................................................................................- 47 -
4.6 Motor parameter self-tuning..................................................................................................- 47 -
CHAPTER 5 FUNCTION PRAMETER TABLE.......................................- 49 -
5.1 Function Parameter Table......................................................................................................- 49 -
5.2 Function Groups.......................................................................................................................- 49 -
CHAPTER 6 FUNCTION PARAMETER SPECIFICATION.....................- 65 -
6.1 F0 Basic Parameters................................................................................................................- 65 -
6.2 F1 Group Motor parameters...............................................................................................- 67 -
6.3 F2 Vector control factors........................................................................................................- 70 -
6.4 F3 Startup/stop control parameters....................................................................................- 72 -
6.5 F4 Group Input terminal.......................................................................................................- 77 -6.6 F5 Group Output terminal...................................................................................................- 79 -
6.7 F6 Group Speed parameters..............................................................................................- 82 -
6.8 F7 Group Curve parameters...............................................................................................- 86 -
6.9 F8 Group Keyboard parameters........................................................................................- 88 -
6.10 F9 Group Fault and protection........................................................................................- 92 -
6.11 FA Group PG parameters................................................................................................- 95 -
6.12 FB Group Communication parameters.........................................................................- 96 -
6.13 FC Group Special enhancement function....................................................................- 96 -
6.14 FD Group Special function parameters.......................................................................- 100 -
6.15 FP Group User shortcut parameters............................................................................- 101 -
CHAPTER 7 APPLICATION AND ADJUSTMENT.............................- 103 -
7.1 Multi-stage speed control mode.........................................................................................- 103 -
7.2 Analogue control mode........................................................................................................- 109 -
7.3 Inspection running.................................................................................................................- 111 -
7.4 Power failure emergency running......................................................................................- 113 -
7.5 Analogue weighing adjustment..........................................................................................- 116 -
7.6 Weighingless adjustment method.....................................................................................- 118 -
CHAPTER 8 FAULTS-CAUSES-REMEDIES.......................................- 121 -
8.1 Fault alarm and remedies.....................................................................................................- 121 -
8.2 Common faults and remedies.............................................................................................- 121 -Safety Information and NotesSafety Information and Notes ME320L(N)Elevator Specialized Inverter User Manual
Chapter 1 Safety information and Notes
Safety definition:
There are two kinds of safety items in this manual:
Danger
Failure to follow the instructions will result in death or serious injury.
Note
Failure to follow these instructions can result in medium hurt or equipment
Preface
Thanks for using the products of Suzhou Monarch Control Technology Co.,
Ltd.ME320L(N)is a new generation of elevator specialized vector control
inverter, which is under the research and development of Suzhou Monarch
Control Technology Co., Ltd. It’s the result of many years’ experience in
elevator area, motor vector control and advanced algorithms like smooth curve
calculation, It’s the most practical, professional and easiest to use specialized
inverter! Its main features are as follows:
● Applies to the driving control of permanent-magnet synchronous motor
and asynchronous motor, possessing different kinds of rotary encoder
interfaces;
● Self-tuning function of motor parameters, including static tuning and full
tuning;
● Quick startup of curve processing, multi-stage S curve settings and
4-stage acceleration and deceleration time settings ensure the sense of
comfort during the running of the elevator;
● Simple and practical battery running function, the input of 48V power
supply can complete self-help when power is off;
● Enable inspection、brake contactor control, output contactor control,
forced deceleration judgment, over speed testing, speed deviation testing,
advanced door open, contact conglutination testing, motor overheat
testing, startup pre-torque compensation and other elevator special
functions make elevator control easier;
● The unique one-button design on the operation panel make complicated
keyboard operation easy; that it can be put anywhere through RJ45
terminal make elevator adjustment convenient and simple; parameter
copy unit make batch adjustment easy;
● Built-in DC reactor and braking unit improve output power factor of the
system and reduce the cost of outside components of the electrical
system;
● The whole series of independent duct design, professional lightning
protection design, professional manufacture platform and advanced
processs control ensure the quality of ME320L(N) specialized inverter;
● Please read and master this operating instruction, which is the attachmentPreface ME320L(N)Elevator Specialized InverterUser Manual
of the inverter, before using ME320L(N) inverter, and keep the instruction
well after reading.
The content of the manual has been conformed before print. However, our
company is devoted to perfecting and improving the products, so we keep the
right of revising product specifications, performance and other parts of the
manual. Sorry for no special notification if there’re any changes.
Suzhou Monarch Control Technology Co., Ltd provides all-round technical
support for customers. If there’re any questions, please contact Product Sales
Center or Customer Service Center of Monarch.Contents
PREFACE........................................................................................................1
CHAPTER 1 SAFETY INFORMATION AND NOTES.................................- 1 -
1.1 Safety Items..................................................................................................................................- 1 -
CHAPTER 2 PRODUCT INFORMATION...............................................- 9 -
2.1 Naming rules................................................................................................................................- 9 -
2.2 Nameplate.....................................................................................................................................- 9 -
2.3 Main models of ME320L(N) inverters(Including IP model)......................................- 10 -
2.4 Technical Specification...........................................................................................................- 10 -
2.5 Product figure and stallation hole size (IP model included)..................................- 12 -
2.6 Options(IP model included)..............................................................................................- 15 -
2.7 Daily maintenance of inverter...............................................................................................- 15 -
CHAPTER 3 INSTALLATION AND WIRING.............................................- 21 -
3.1 Mechanical Installation...........................................................................................................- 21 -
3.2 Electric Installation..................................................................................................................- 23 -
CHAPTER 4 OPERATION AND TEST-RUN OF THE INVERTER............- 41 -
4.1 Terms of ME320L(N) Inverter................................................................................................- 41 -
4.2 Introduction of operation and display panel.....................................................................- 42 -
4.3 Function codes examination and operation instruction...............................................- 43 -
4.4 Operation of shortcut menu..................................................................................................- 45 -
4.5 Password setting......................................................................................................................- 47 -
4.6 Motor parameter self-tuning..................................................................................................- 47 -
CHAPTER 5 FUNCTION PRAMETER TABLE.......................................- 49 -
5.1 Function Parameter Table......................................................................................................- 49 -
5.2 Function Groups.......................................................................................................................- 49 -
CHAPTER 6 FUNCTION PARAMETER SPECIFICATION.....................- 65 -
6.1 F0 Basic Parameters................................................................................................................- 65 -
6.2 F1 Group Motor parameters...............................................................................................- 67 -
6.3 F2 Vector control factors........................................................................................................- 70 -
6.4 F3 Startup/stop control parameters....................................................................................- 72 -
6.5 F4 Group Input terminal.......................................................................................................- 77 -6.6 F5 Group Output terminal...................................................................................................- 79 -
6.7 F6 Group Speed parameters..............................................................................................- 82 -
6.8 F7 Group Curve parameters...............................................................................................- 86 -
6.9 F8 Group Keyboard parameters........................................................................................- 88 -
6.10 F9 Group Fault and protection........................................................................................- 92 -
6.11 FA Group PG parameters................................................................................................- 95 -
6.12 FB Group Communication parameters.........................................................................- 96 -
6.13 FC Group Special enhancement function....................................................................- 96 -
6.14 FD Group Special function parameters.......................................................................- 100 -
6.15 FP Group User shortcut parameters............................................................................- 101 -
CHAPTER 7 APPLICATION AND ADJUSTMENT.............................- 103 -
7.1 Multi-stage speed control mode.........................................................................................- 103 -
7.2 Analogue control mode........................................................................................................- 109 -
7.3 Inspection running.................................................................................................................- 111 -
7.4 Power failure emergency running......................................................................................- 113 -
7.5 Analogue weighing adjustment..........................................................................................- 116 -
7.6 Weighingless adjustment method.....................................................................................- 118 -
CHAPTER 8 FAULTS-CAUSES-REMEDIES.......................................- 121 -
8.1 Fault alarm and remedies.....................................................................................................- 121 -
8.2 Common faults and remedies.............................................................................................- 121 -Safety Information and NotesSafety Information and Notes ME320L(N)Elevator Specialized Inverter User Manual
Chapter 1 Safety information and Notes
Safety definition:
There are two kinds of safety items in this manual:
Danger
Failure to follow the instructions will result in death or serious injury.
Note
Failure to follow these instructions can result in medium hurt or equipment
AIGC
內(nèi)容描述:
The ME320L Elevator-專享變頻器 User Manual (in English) is a comprehensive guide designed for the specific application of the ME320L series elevator變頻器, which is tailored to meet the requirements and performance standards of elevator systems. It provides in-depth technical details, instructions, and operational guidelines for installing, configuring, and maintaining this advanced變頻器.
This manual typically covers topics such as:
1. **Product overview**: Introducing the ME320L elevator變頻器's features, specifications, and system architecture.
2. **Hardware description**: Explains the various components of the變頻器, including input/output connections, control boards, power modules, and communication interfaces.
3. **Installation procedures**: Step-by-step guidance on mounting, wiring, and grounding the ME320L for safe and proper integration into an elevator drive system.
4. **Configuration**: Detailed explanation of parameter settings for motor speed control, torque management, current limiting, and elevator operation modes.
5. **Operation and control**: Instructions for using the變頻器's interface (HMI or remote control), including start-up, acceleration, deceleration, and emergency stop procedures.
6. **Monitoring and diagnostics**: Descriptions of built-in monitoring functions, alarm conditions, and troubleshooting techniques for common issues.
7. **Safety precautions**: Emphasizes safety measures, electrical codes, and regulations related to the installation, operation, and maintenance of the elevator-specific ME320L變頻器.
8. **Maintenance and service**: Guidelines for routine inspections, cleaning, component replacement, and recommended service intervals.
By following the ME320L Elevator-專享變頻器 User Manual (English), users can ensure optimal performance, reliability, and longevity of the elevator drive system while adhering to industry best practices and regulatory standards.
相關(guān)資源推薦