MIXO modular units for multipole connectors
(cid:14)
Characteristics
(cid:4)
(cid:2) electric contacts in silver-plated or gold-plated brass with
connections to the conductors via crimping.
(cid:3) pneumatic contacts in plastic with insertion tube connection. (cid:5)
(cid:4) modular inserts of identical size with insertion system for
forming the complete module and frame lock tab.
(cid:5) inserts in self-extinguishing thermosplastic material, reinforced (cid:6)
with glass fibre, UL 94-V0 approved, with a working
(cid:3)
temperature range of -40 °C to +125 °C.
(cid:6) inserts in conformance with the requirements of the
EN 61984 standard and certified and marked with the UL,
CSA, CCC, GLmarks. (cid:7)
(cid:7) inserts with asymmetric guide rails to prevent incorrect
coupling.
(cid:8) position of contacts identified with numbers or codes on both (cid:8)
sides of every insert.
(cid:15)
(cid:9) male/female module carrier frames with mandatory housings
and polarity, in die-cast zinc alloy.
(cid:9)
(cid:10) module lock tab, may be divided according to the number of
modules used; guarantees a perfect stability of the modules
during wiring and coupling/uncoupling of the connectors.
(cid:11) asymmetric earth contacts (two for frame) with wide contact (cid:10)
surface prevent incorrect coupling; when two or more identical
connectors of the MIXO series are used, coded pins prevent
incorrect coupling (see Catalogue CN.07).
(cid:11)
(cid:12) captive frame fastening screws, with flexible spring washer.
(cid:13) dummy module for unused frame slots.
(cid:12)
(cid:13)
inserts contact signal connectors and tubes rated rated No. of modules
type type connections current A voltage V footprint
CX 01 YF/M main electric crimp 200 1000 2
CX 02 GF/M main electric crimp 100 1000 2
CX 02 4AF/M main electric axial screw 40 1000 1
CX 03 4F/M main electric crimp 40 400/690 1
CX 05 SF/M main electric spring 16 400 1
CX 06 CF/M main electric crimp 16 500 1
CX 08 CF/M main electric crimp 16 400 1
CX 20 CF/M main electric crimp 16 500 2
CX 12 DF/M main / auxiliary electric crimp 10 250 1
CX 02 HF/M main electric crimp 16 2900/5000 2
CX 02 BF/M multiaxial connectors see CX 04 B --- --- --- 2
CX 01 BF/M main / auxiliary + shield electric crimp 10 50 ---
CX 04 BF/M main / auxiliary + shield electric crimp 10 50 ---
CX 03 P pneumatic ? 1.6 - 3.0 - 4.0 mm gas / liquid ** insertion --- --- 1
CX 02 P pneumatic ? 6.0 mm gas / liquid ** insertion --- --- 1
CX FM none (dummy module) --- --- --- --- 1
CX 01 JF RJ45 + auxiliary electric crimp --- --- 2
CX 02 JF RJ45 + auxiliary electric crimp --- --- 3
** Warning: For obvious reasons of safety, the VDE standard does not permit electric contacts to be present within the same connector group together with contacts for the
transmission of liquids. In addition, the use of pneumatic air contacts requires an appropriate filtering and dehydration system to prevent dangerous condensation.
Contacts may be used for pressure values of up to a maximum of 8 bar/116 psi.MIXO modular units 1 pole 200A - 1000V
modular units, 200Asilver plated crimp contacts
the modular inserts must be installed in suitable crimp connections
frames which in turn are installed in traditional
housings * or COB panel support
frames for modular units*........page: 151**
* enclosures: housings or high construction hoods
description part No. part No.
without contacts (to be ordered separately)
- female inserts for female contacts CX 01 YF
- male inserts for female contacts CX 01 YM
200Afemale crimp contacts
25 mm2 --- with no grooves CYFA25
35 mm2 AWG 2 one groove CYFA35
50 mm2 AWG 1 two grooves CYFA50
70 mm2 AWG 2/0 with no grooves CYFA70
200Amale crimp contacts
25 --- with no grooves CYMA25
35 mm2 AWG 2 one groove CYMA35
50 mm2 AWG 1 two grooves CYMA50
70 mm2 AWG 2/0 with no grooves CYMA70
dimensions in mm dimensions in mm
34 29.4
M ? A
52,3
40
? 20
? 9.5
F
? 20
57.8 38
? A
contacts side (front view)
side with reference arrow▲
F M
dimensions shown are not binding
and may be changed without notice
detalp
revlis
- characteristics according to EN 61984:
200A 1000V 8kV 3
- certifications: (E ), (Q), (R); thecertifications
(cid:14)
Characteristics
(cid:4)
(cid:2) electric contacts in silver-plated or gold-plated brass with
connections to the conductors via crimping.
(cid:3) pneumatic contacts in plastic with insertion tube connection. (cid:5)
(cid:4) modular inserts of identical size with insertion system for
forming the complete module and frame lock tab.
(cid:5) inserts in self-extinguishing thermosplastic material, reinforced (cid:6)
with glass fibre, UL 94-V0 approved, with a working
(cid:3)
temperature range of -40 °C to +125 °C.
(cid:6) inserts in conformance with the requirements of the
EN 61984 standard and certified and marked with the UL,
CSA, CCC, GLmarks. (cid:7)
(cid:7) inserts with asymmetric guide rails to prevent incorrect
coupling.
(cid:8) position of contacts identified with numbers or codes on both (cid:8)
sides of every insert.
(cid:15)
(cid:9) male/female module carrier frames with mandatory housings
and polarity, in die-cast zinc alloy.
(cid:9)
(cid:10) module lock tab, may be divided according to the number of
modules used; guarantees a perfect stability of the modules
during wiring and coupling/uncoupling of the connectors.
(cid:11) asymmetric earth contacts (two for frame) with wide contact (cid:10)
surface prevent incorrect coupling; when two or more identical
connectors of the MIXO series are used, coded pins prevent
incorrect coupling (see Catalogue CN.07).
(cid:11)
(cid:12) captive frame fastening screws, with flexible spring washer.
(cid:13) dummy module for unused frame slots.
(cid:12)
(cid:13)
inserts contact signal connectors and tubes rated rated No. of modules
type type connections current A voltage V footprint
CX 01 YF/M main electric crimp 200 1000 2
CX 02 GF/M main electric crimp 100 1000 2
CX 02 4AF/M main electric axial screw 40 1000 1
CX 03 4F/M main electric crimp 40 400/690 1
CX 05 SF/M main electric spring 16 400 1
CX 06 CF/M main electric crimp 16 500 1
CX 08 CF/M main electric crimp 16 400 1
CX 20 CF/M main electric crimp 16 500 2
CX 12 DF/M main / auxiliary electric crimp 10 250 1
CX 02 HF/M main electric crimp 16 2900/5000 2
CX 02 BF/M multiaxial connectors see CX 04 B --- --- --- 2
CX 01 BF/M main / auxiliary + shield electric crimp 10 50 ---
CX 04 BF/M main / auxiliary + shield electric crimp 10 50 ---
CX 03 P pneumatic ? 1.6 - 3.0 - 4.0 mm gas / liquid ** insertion --- --- 1
CX 02 P pneumatic ? 6.0 mm gas / liquid ** insertion --- --- 1
CX FM none (dummy module) --- --- --- --- 1
CX 01 JF RJ45 + auxiliary electric crimp --- --- 2
CX 02 JF RJ45 + auxiliary electric crimp --- --- 3
** Warning: For obvious reasons of safety, the VDE standard does not permit electric contacts to be present within the same connector group together with contacts for the
transmission of liquids. In addition, the use of pneumatic air contacts requires an appropriate filtering and dehydration system to prevent dangerous condensation.
Contacts may be used for pressure values of up to a maximum of 8 bar/116 psi.MIXO modular units 1 pole 200A - 1000V
modular units, 200Asilver plated crimp contacts
the modular inserts must be installed in suitable crimp connections
frames which in turn are installed in traditional
housings * or COB panel support
frames for modular units*........page: 151**
* enclosures: housings or high construction hoods
description part No. part No.
without contacts (to be ordered separately)
- female inserts for female contacts CX 01 YF
- male inserts for female contacts CX 01 YM
200Afemale crimp contacts
25 mm2 --- with no grooves CYFA25
35 mm2 AWG 2 one groove CYFA35
50 mm2 AWG 1 two grooves CYFA50
70 mm2 AWG 2/0 with no grooves CYFA70
200Amale crimp contacts
25 --- with no grooves CYMA25
35 mm2 AWG 2 one groove CYMA35
50 mm2 AWG 1 two grooves CYMA50
70 mm2 AWG 2/0 with no grooves CYMA70
dimensions in mm dimensions in mm
34 29.4
M ? A
52,3
40
? 20
? 9.5
F
? 20
57.8 38
? A
contacts side (front view)
side with reference arrow▲
F M
dimensions shown are not binding
and may be changed without notice
detalp
revlis
- characteristics according to EN 61984:
200A 1000V 8kV 3
- certifications: (E ), (Q), (R); thecertifications
AIGC
尊敬的用戶,200安培插芯模塊是一種專門針對(duì)電力傳輸和分配需求設(shè)計(jì)的電氣元件。它通常指的是插座或連接器類型的產(chǎn)品,其額定電流容量為200安培,這意味著該模塊能夠安全地承載和通過最大200安培的電流量。這種高電流等級(jí)的插芯模塊廣泛應(yīng)用于工業(yè)、建筑、電動(dòng)汽車充電設(shè)施以及一些大型電器設(shè)備的供電接口,以確保在大電流負(fù)荷下穩(wěn)定、安全的工作。在使用時(shí),請務(wù)必遵循相關(guān)的電氣安裝規(guī)范和安全操作指南,確保正確選擇和接線使用。如有更多關(guān)于此類產(chǎn)品的問題或需要技術(shù)支持,請隨時(shí)咨詢。