SAMCO-vm05.Insruction.Manual.EN
聲明:您必須遵守我們的協(xié)議,如果您下載了該資源行為將被視為對《電天下賬號管理規(guī)范》全部內(nèi)容的認可,本網(wǎng)站資源來自原創(chuàng),僅供用于學習和交流,請勿用于商業(yè)用途。如有侵權(quán)、不妥之處,請舉報本資源,我們將及時審核處理!
SAMCO-vm05.Insruction.Manual.EN
文本預覽
High performance multifunction quiet inverter
VVVF Inverter
INSTRUCTION MANUAL
200 V systems
SBT-0.75K/1.5K to SBT 22K/30K for general industry, fan and pump
400 V systems
SHF-1.5K to SHF-55K for general industry
SPF-2.2K to SPF-75K for fan and pump
SANKEN ELECTRIC CO., LTD.Thank you for purchasing the Sanken general-purpose inverter. This inverter is
designed to drive an induction motor at a variable speed. The inverter has a built-in microcom-
puter providing a wide range of functions and easy operability. To ensure many years of trouble-
free operation and maintain optimum performance, be sure to read through this manual before
using the product.
[For Safe Use]
(cid:132) Safety instructions are given in this manual and on the product to prevent physical injury to
yourself or others, or damage to property.
Read the instructions thoroughly and use the product correctly.
(cid:132) After reading, keep this manual to hand for reference.
(cid:132) Critical safety instructions are marked “Danger” or “Caution” as follows:
This symbol indicates a hazard that could lead to death or serious injury if
Danger
the warning is ignored and the product is handled incorrectly.
This symbol indicates a hazard that could lead to injury or damage to
Caution
property if the warning is ignored and the product is handled incorrectly.
*Even ignoring an instruction marked “Caution” can have serious consequences under some
circumstances. Be sure to abide by all instructions, irrespective of the degree of danger.
Meanings of symbols
This symbol indicates a potential danger.
The specific danger is indicated in the symbol. (This example indicates a
general danger.)
This symbol indicates the need for caution.
The specific caution is indicated in the symbol. (This example indicates a
general caution.)
This symbol indicates a prohibition.
The specific prohibited action is indicated in the symbol. (This example indi-
cates a general prohibition.)
This symbol indicates an action that must be performed.
The specific action is indicated in the symbol. (This example indicates a gen-
eral requirement.)Safety Notes
1. Mount the inverter on a strong metal panel or similar surface using the specified
screws.
2. Ground the inverter and the motor using their ground terminals ( ).
3. Install a circuit breaker (MCCB) of the appropriate capacity between the inverter and
the power supply.
4. The inverter incorporates high-voltage circuitry that could cause an electric shock or
other physical injury. Do not touch the inside of the inverter.
5. When carrying out maintenance or inspection, turn the power off and check with a
circuit tester that there is no voltage between X and P on the terminal board after the
CHARGE lamp goes out.
6. Some internal components in the inverter retain an electric change even when the
inverter is not operating. Do not touch the terminal board.
7. When using a power supply with a frequency of 60 Hz or more, check the safety of the
load, including the motor and so on.
8. Turn the power off when not using the inverter for a long time.
9. This inverter is made for domestic use. Please consult us before exporting this
product.Contents
1. Safety Notes.....................................................................................................................................1
1.1 Notes on Installation.....................................................................................................................1
1.2 Notes on Wiring ...........................................................................................................................1
1.3 Notes on Operation......................................................................................................................2
1.4 Notes on Maintenance and Inspection...........................................................................................2
1.5 Disposal.......................................................................................................................................3
1.6 Others..........................................................................................................................................3
2. Checking the Product and Precautions on Use ...................................................................................4
2.1 Checking the Product ...................................................................................................................4
2.2 Precautions on Use.......................................................................................................................5
3. Installation.........................................................................................................................................6
3.1 Installation Location......................................................................................................................6
3.2 Installation Direction and Space ....................................................................................................7
3.3 Removing and Attaching the Front Cover......................................................................................8
3.3.1 Small-capacity model (200V type SBT-3.7K/5.5K or less, 400V type SHF-4.0K or less, 400V
type SPF-5.5K or less)............................................................................................................8
3.3.2 Middle- or large-capacity model (200V type SBT-5.5K/7.5K or more, 400V type SHF-5.5K
or more, 400V type SPF-7.5K or more)..................................................................................9
3.4 Removing and Attaching the Operation Panel ................................................................................9
3.4.1 Small-capacity model (200V type SBT-3.7K/5.5K or less, 400V type SHF-4.0K or less, 400V
type SPF-5.5K or less)............................................................................................................9
3.4.2 Middle- or large-capacity model (200V type SBT-5.5K/7.5K or more, 400V type SHF-5.5K
or more, 400V type SPF-7.5K or more)..................................................................................9
4. Wiring.............................................................................................................................................10
4.1 Wiring Instructions......................................................................................................................10
4.2 Terminal Connection Diagrams....................................................................................................13
5. Operation Panel ..............................................................................................................................24
5.1 Section Names...........................................................................................................................24
5.2 Operation Panel Keys ................................................................................................................24
5.3 Display Modes...........................................................................................................................25
6. Operation........................................................................................................................................27
6.1 Preliminary Checks.....................................................................................................................27
6.2 Test Run.....................................................................................................................................27
6.3 Operation...................................................................................................................................28
6.3.1 Operation through the operation panel (Status Display mode)..................................................28
6.3.2 Operation with external signals ...............................................................................................29
6.3.3 Jog operation.........................................................................................................................30
6.3.4 Hold operation.......................................................................................................................31
6.3.5 Notes on free run stop terminal (MBS)...................................................................................31
6.4 Reading Alarm Data ...................................................................................................................32
6.5 Operational Error Displays .........................................................................................................33
6.6 Conflict Error Displays ...............................................................................................................346.7 Other Displays ...........................................................................................................................36
6.8 Definition of Technical Terms ......................................................................................................37
VVVF Inverter
INSTRUCTION MANUAL
200 V systems
SBT-0.75K/1.5K to SBT 22K/30K for general industry, fan and pump
400 V systems
SHF-1.5K to SHF-55K for general industry
SPF-2.2K to SPF-75K for fan and pump
SANKEN ELECTRIC CO., LTD.Thank you for purchasing the Sanken general-purpose inverter. This inverter is
designed to drive an induction motor at a variable speed. The inverter has a built-in microcom-
puter providing a wide range of functions and easy operability. To ensure many years of trouble-
free operation and maintain optimum performance, be sure to read through this manual before
using the product.
[For Safe Use]
(cid:132) Safety instructions are given in this manual and on the product to prevent physical injury to
yourself or others, or damage to property.
Read the instructions thoroughly and use the product correctly.
(cid:132) After reading, keep this manual to hand for reference.
(cid:132) Critical safety instructions are marked “Danger” or “Caution” as follows:
This symbol indicates a hazard that could lead to death or serious injury if
Danger
the warning is ignored and the product is handled incorrectly.
This symbol indicates a hazard that could lead to injury or damage to
Caution
property if the warning is ignored and the product is handled incorrectly.
*Even ignoring an instruction marked “Caution” can have serious consequences under some
circumstances. Be sure to abide by all instructions, irrespective of the degree of danger.
Meanings of symbols
This symbol indicates a potential danger.
The specific danger is indicated in the symbol. (This example indicates a
general danger.)
This symbol indicates the need for caution.
The specific caution is indicated in the symbol. (This example indicates a
general caution.)
This symbol indicates a prohibition.
The specific prohibited action is indicated in the symbol. (This example indi-
cates a general prohibition.)
This symbol indicates an action that must be performed.
The specific action is indicated in the symbol. (This example indicates a gen-
eral requirement.)Safety Notes
1. Mount the inverter on a strong metal panel or similar surface using the specified
screws.
2. Ground the inverter and the motor using their ground terminals ( ).
3. Install a circuit breaker (MCCB) of the appropriate capacity between the inverter and
the power supply.
4. The inverter incorporates high-voltage circuitry that could cause an electric shock or
other physical injury. Do not touch the inside of the inverter.
5. When carrying out maintenance or inspection, turn the power off and check with a
circuit tester that there is no voltage between X and P on the terminal board after the
CHARGE lamp goes out.
6. Some internal components in the inverter retain an electric change even when the
inverter is not operating. Do not touch the terminal board.
7. When using a power supply with a frequency of 60 Hz or more, check the safety of the
load, including the motor and so on.
8. Turn the power off when not using the inverter for a long time.
9. This inverter is made for domestic use. Please consult us before exporting this
product.Contents
1. Safety Notes.....................................................................................................................................1
1.1 Notes on Installation.....................................................................................................................1
1.2 Notes on Wiring ...........................................................................................................................1
1.3 Notes on Operation......................................................................................................................2
1.4 Notes on Maintenance and Inspection...........................................................................................2
1.5 Disposal.......................................................................................................................................3
1.6 Others..........................................................................................................................................3
2. Checking the Product and Precautions on Use ...................................................................................4
2.1 Checking the Product ...................................................................................................................4
2.2 Precautions on Use.......................................................................................................................5
3. Installation.........................................................................................................................................6
3.1 Installation Location......................................................................................................................6
3.2 Installation Direction and Space ....................................................................................................7
3.3 Removing and Attaching the Front Cover......................................................................................8
3.3.1 Small-capacity model (200V type SBT-3.7K/5.5K or less, 400V type SHF-4.0K or less, 400V
type SPF-5.5K or less)............................................................................................................8
3.3.2 Middle- or large-capacity model (200V type SBT-5.5K/7.5K or more, 400V type SHF-5.5K
or more, 400V type SPF-7.5K or more)..................................................................................9
3.4 Removing and Attaching the Operation Panel ................................................................................9
3.4.1 Small-capacity model (200V type SBT-3.7K/5.5K or less, 400V type SHF-4.0K or less, 400V
type SPF-5.5K or less)............................................................................................................9
3.4.2 Middle- or large-capacity model (200V type SBT-5.5K/7.5K or more, 400V type SHF-5.5K
or more, 400V type SPF-7.5K or more)..................................................................................9
4. Wiring.............................................................................................................................................10
4.1 Wiring Instructions......................................................................................................................10
4.2 Terminal Connection Diagrams....................................................................................................13
5. Operation Panel ..............................................................................................................................24
5.1 Section Names...........................................................................................................................24
5.2 Operation Panel Keys ................................................................................................................24
5.3 Display Modes...........................................................................................................................25
6. Operation........................................................................................................................................27
6.1 Preliminary Checks.....................................................................................................................27
6.2 Test Run.....................................................................................................................................27
6.3 Operation...................................................................................................................................28
6.3.1 Operation through the operation panel (Status Display mode)..................................................28
6.3.2 Operation with external signals ...............................................................................................29
6.3.3 Jog operation.........................................................................................................................30
6.3.4 Hold operation.......................................................................................................................31
6.3.5 Notes on free run stop terminal (MBS)...................................................................................31
6.4 Reading Alarm Data ...................................................................................................................32
6.5 Operational Error Displays .........................................................................................................33
6.6 Conflict Error Displays ...............................................................................................................346.7 Other Displays ...........................................................................................................................36
6.8 Definition of Technical Terms ......................................................................................................37
AIGC
SAMCO-vm05 Instruction Manual EN
The title "SAMCO-vm05.Instruction.Manual.EN" refers to the user manual for a product specifically designed by SAMCO, a well-known electrical or electronic component manufacturer. The "vm05" in the model number likely indicates a particular voltage management or control module, and "Instruction Manual" is the guide that provides users with detailed information on how to install, operate, maintain, and troubleshoot this device.
The ".EN" at the end signifies that the manual is in English language, which means it contains instructions and technical specifications written in English to cater to English-speaking customers. This document would typically cover topics such as wiring diagrams, safety precautions, operational procedures, adjustments, and any troubleshooting steps required for optimal performance of the SAMCO vm05 module.
To summarize, the SAMCO-vm05 Instruction Manual (English) serves as an essential resource for individuals who own or are using the vm05 voltage management module to ensure they can effectively utilize its features and functions while maintaining compliance with safety standards and best practices.