UPS 操作手冊(cè)
40–60–80–100–125–160–200–250–300kVA
1開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
1. 簡(jiǎn)介...........................................................................................................4
2. 開(kāi)機(jī)程序....................................................................................................4
2.1 開(kāi)機(jī)故障分析........................................................................................................6
3. 關(guān)機(jī)程序....................................................................................................7
4. 維修旁路操作程序......................................................................................7
5. 從維修旁路開(kāi)機(jī).........................................................................................8
面板操作手冊(cè)
1. 簡(jiǎn)介:......................................................................................................9
2. 描述 .........................................................................................................9
2.1 模擬圖描述:........................................................................................................9
2.2 告警及操作狀態(tài) ..................................................................................................10
3. LCD 顯示管理........................................................................................12
3.1 缺省顯示.............................................................................................................12
3.2 主菜單.................................................................................................................12
3.3 測(cè)量....................................................................................................................13
3.3.1 輸出..............................................................................................................14
3.3.2 旁路..............................................................................................................14
3.3.3 逆變器 ..........................................................................................................15
3.3.4 AC/DC交直轉(zhuǎn)換............................................................................................15
3.3.5 電池..............................................................................................................15
3.4 告警....................................................................................................................16
3.4.1 UPS狀態(tài).......................................................................................................16
23.4.2 歷史記錄.......................................................................................................17
3.4.3 告警及狀態(tài)信息列表.....................................................................................18
3.5 SPECIAL菜單........................................................................................................19
3.5.1 復(fù)位..............................................................................................................19
3.5.2 時(shí)間設(shè)置.......................................................................................................20
3.5.3 Ups測(cè)試.......................................................................................................20
3.5.4 電池測(cè)試.......................................................................................................20
3.5.5 清除歷史告警................................................................................................20
3.6 菜單結(jié)構(gòu)圖..........................................................................................................20
3開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
1. 簡(jiǎn)介
在執(zhí)行本章所述的任何操作步驟前,仔細(xì)閱讀指導(dǎo),以避免錯(cuò)誤操作可能造成的人員
傷害或設(shè)備損壞。
2. 開(kāi)機(jī)程序
警告
合UPS開(kāi)關(guān)前,應(yīng)確保:
- 位于面板附近的EPO緊急電源關(guān)斷按鈕處于釋放狀態(tài);否則,釋放該按鈕,然后
執(zhí)行開(kāi)機(jī)步驟。
- 輸入輸出相序正確。
注意
電池開(kāi)關(guān)BCB安裝在外部。
警告
在面板提示合電池開(kāi)關(guān)之前禁止合閘。否則,在整流器啟動(dòng)之前,可能對(duì)UPS內(nèi)部器件及
電池造成嚴(yán)重?fù)p壞。
Nr. 液晶顯示 操作 UPS 工作狀態(tài)
1 無(wú)顯示 合整流器開(kāi)關(guān)RCB
2 UPS START UP 整流器開(kāi)始供電,電壓逐漸升至額定值。
PLEASE WAIT 面板上所有綠燈均點(diǎn)亮。
UPS啟動(dòng),請(qǐng)稍候 微處理器檢測(cè)所有啟動(dòng)狀態(tài)正常。LED1和
LED3燈亮。
3 BOOSTER START UP IGBT整流器開(kāi)始工作,逆變器輸入電壓升至
PLEASE WAIT 額定值。 LED 3 綠燈亮。
內(nèi)部升壓?jiǎn)?dòng)中
4 INVERTER START UP 逆變橋開(kāi)始工作,輸出交流電壓達(dá)到額定值。
PLEASE WAIT 幾秒鐘后,靜態(tài)開(kāi)關(guān)閉合。LED5 綠燈亮。
逆變器啟動(dòng)中
5 BYPASS START UP
合旁路開(kāi)關(guān)SBCB
CLOSE SBCB
旁路啟動(dòng),合SBCB
46 BYPASS START UP 微處理器檢測(cè)所有旁路參數(shù)(電壓、相序、頻
PLEASE WAIT 率)在正常范圍內(nèi)。LED2綠燈亮。
旁路啟動(dòng)中
開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
7 BATTERY START UP
合電池開(kāi)關(guān)BCB
CLOSE BCB
電池啟動(dòng),合BCB
8 BATTERY START UP 微處理器檢測(cè)所有狀態(tài)正確。LED4綠燈亮。
PLEASE WAIT
電池啟動(dòng)中
9 START UP END
合輸出開(kāi)關(guān)OCB
CLOSE OCB
啟動(dòng)結(jié)束,合OCB
10 START UP END 微處理器檢測(cè)所有輸出參數(shù) (電壓、電流、頻
PLEASE WAIT 率)在正常范圍內(nèi)。LED7綠燈亮。
啟動(dòng)結(jié)束
End UPS MODEL 一段時(shí)間后,顯示缺省畫(huà)面。
VOLTAGE OUTPUT
UPS狀態(tài)顯示
5開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
2.1 開(kāi)機(jī)故障分析
在開(kāi)機(jī)過(guò)程中出現(xiàn)某些告警時(shí),可以根據(jù)本章進(jìn)行初步分析。若故障仍不能解決,請(qǐng)聯(lián)系
維修部門(mén)。
1) 在合整流器輸入開(kāi)關(guān)RCB后,LCD屏仍舊無(wú)顯示
? 檢查輸入相序
? 檢查整流保險(xiǎn);保險(xiǎn)安裝于UPS內(nèi)部。
2) 啟動(dòng)步驟2后不再進(jìn)行到步驟3,且顯示告警A1 – Network failure
? 檢查告警A2是否激活,檢查輸入相序。
? 檢查整流保險(xiǎn) F1-F2-F3.
3) 啟動(dòng)步驟3后,UPS 顯示告警信息
? 斷開(kāi)整流開(kāi)關(guān),檢查接線
? 合整流開(kāi)關(guān),重新啟動(dòng)UPS
4) 啟動(dòng)步驟 4后,UPS 顯示告警信息
40–60–80–100–125–160–200–250–300kVA
1開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
1. 簡(jiǎn)介...........................................................................................................4
2. 開(kāi)機(jī)程序....................................................................................................4
2.1 開(kāi)機(jī)故障分析........................................................................................................6
3. 關(guān)機(jī)程序....................................................................................................7
4. 維修旁路操作程序......................................................................................7
5. 從維修旁路開(kāi)機(jī).........................................................................................8
面板操作手冊(cè)
1. 簡(jiǎn)介:......................................................................................................9
2. 描述 .........................................................................................................9
2.1 模擬圖描述:........................................................................................................9
2.2 告警及操作狀態(tài) ..................................................................................................10
3. LCD 顯示管理........................................................................................12
3.1 缺省顯示.............................................................................................................12
3.2 主菜單.................................................................................................................12
3.3 測(cè)量....................................................................................................................13
3.3.1 輸出..............................................................................................................14
3.3.2 旁路..............................................................................................................14
3.3.3 逆變器 ..........................................................................................................15
3.3.4 AC/DC交直轉(zhuǎn)換............................................................................................15
3.3.5 電池..............................................................................................................15
3.4 告警....................................................................................................................16
3.4.1 UPS狀態(tài).......................................................................................................16
23.4.2 歷史記錄.......................................................................................................17
3.4.3 告警及狀態(tài)信息列表.....................................................................................18
3.5 SPECIAL菜單........................................................................................................19
3.5.1 復(fù)位..............................................................................................................19
3.5.2 時(shí)間設(shè)置.......................................................................................................20
3.5.3 Ups測(cè)試.......................................................................................................20
3.5.4 電池測(cè)試.......................................................................................................20
3.5.5 清除歷史告警................................................................................................20
3.6 菜單結(jié)構(gòu)圖..........................................................................................................20
3開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
1. 簡(jiǎn)介
在執(zhí)行本章所述的任何操作步驟前,仔細(xì)閱讀指導(dǎo),以避免錯(cuò)誤操作可能造成的人員
傷害或設(shè)備損壞。
2. 開(kāi)機(jī)程序
警告
合UPS開(kāi)關(guān)前,應(yīng)確保:
- 位于面板附近的EPO緊急電源關(guān)斷按鈕處于釋放狀態(tài);否則,釋放該按鈕,然后
執(zhí)行開(kāi)機(jī)步驟。
- 輸入輸出相序正確。
注意
電池開(kāi)關(guān)BCB安裝在外部。
警告
在面板提示合電池開(kāi)關(guān)之前禁止合閘。否則,在整流器啟動(dòng)之前,可能對(duì)UPS內(nèi)部器件及
電池造成嚴(yán)重?fù)p壞。
Nr. 液晶顯示 操作 UPS 工作狀態(tài)
1 無(wú)顯示 合整流器開(kāi)關(guān)RCB
2 UPS START UP 整流器開(kāi)始供電,電壓逐漸升至額定值。
PLEASE WAIT 面板上所有綠燈均點(diǎn)亮。
UPS啟動(dòng),請(qǐng)稍候 微處理器檢測(cè)所有啟動(dòng)狀態(tài)正常。LED1和
LED3燈亮。
3 BOOSTER START UP IGBT整流器開(kāi)始工作,逆變器輸入電壓升至
PLEASE WAIT 額定值。 LED 3 綠燈亮。
內(nèi)部升壓?jiǎn)?dòng)中
4 INVERTER START UP 逆變橋開(kāi)始工作,輸出交流電壓達(dá)到額定值。
PLEASE WAIT 幾秒鐘后,靜態(tài)開(kāi)關(guān)閉合。LED5 綠燈亮。
逆變器啟動(dòng)中
5 BYPASS START UP
合旁路開(kāi)關(guān)SBCB
CLOSE SBCB
旁路啟動(dòng),合SBCB
46 BYPASS START UP 微處理器檢測(cè)所有旁路參數(shù)(電壓、相序、頻
PLEASE WAIT 率)在正常范圍內(nèi)。LED2綠燈亮。
旁路啟動(dòng)中
開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
7 BATTERY START UP
合電池開(kāi)關(guān)BCB
CLOSE BCB
電池啟動(dòng),合BCB
8 BATTERY START UP 微處理器檢測(cè)所有狀態(tài)正確。LED4綠燈亮。
PLEASE WAIT
電池啟動(dòng)中
9 START UP END
合輸出開(kāi)關(guān)OCB
CLOSE OCB
啟動(dòng)結(jié)束,合OCB
10 START UP END 微處理器檢測(cè)所有輸出參數(shù) (電壓、電流、頻
PLEASE WAIT 率)在正常范圍內(nèi)。LED7綠燈亮。
啟動(dòng)結(jié)束
End UPS MODEL 一段時(shí)間后,顯示缺省畫(huà)面。
VOLTAGE OUTPUT
UPS狀態(tài)顯示
5開(kāi)機(jī)、關(guān)機(jī)和維修旁路操作
2.1 開(kāi)機(jī)故障分析
在開(kāi)機(jī)過(guò)程中出現(xiàn)某些告警時(shí),可以根據(jù)本章進(jìn)行初步分析。若故障仍不能解決,請(qǐng)聯(lián)系
維修部門(mén)。
1) 在合整流器輸入開(kāi)關(guān)RCB后,LCD屏仍舊無(wú)顯示
? 檢查輸入相序
? 檢查整流保險(xiǎn);保險(xiǎn)安裝于UPS內(nèi)部。
2) 啟動(dòng)步驟2后不再進(jìn)行到步驟3,且顯示告警A1 – Network failure
? 檢查告警A2是否激活,檢查輸入相序。
? 檢查整流保險(xiǎn) F1-F2-F3.
3) 啟動(dòng)步驟3后,UPS 顯示告警信息
? 斷開(kāi)整流開(kāi)關(guān),檢查接線
? 合整流開(kāi)關(guān),重新啟動(dòng)UPS
4) 啟動(dòng)步驟 4后,UPS 顯示告警信息
AIGC
尊敬的用戶您好!EA99系列UPS(不間斷電源)操作手冊(cè)是一份詳細(xì)的指南,旨在幫助您正確、安全地安裝、配置和使用EA99系列不間斷電源產(chǎn)品。此手冊(cè)包括了以下內(nèi)容:
1. 產(chǎn)品介紹:對(duì)EA99系列UPS的基礎(chǔ)信息、特性參數(shù)以及適用環(huán)境進(jìn)行說(shuō)明,以便您了解設(shè)備的功能及性能指標(biāo)。
2. 安裝指南:提供UPS的現(xiàn)場(chǎng)安裝步驟,包括設(shè)備布局、電纜連接、接地要求等,確保設(shè)備在滿足規(guī)范條件下穩(wěn)定運(yùn)行。
3. 啟動(dòng)與設(shè)置:指導(dǎo)如何初次開(kāi)機(jī)、進(jìn)入控制面板進(jìn)行基本設(shè)置,如電池測(cè)試、工作模式選擇(市電優(yōu)先或電池供電)、旁路開(kāi)關(guān)操作等。
4. 操作與維護(hù):詳細(xì)介紹日常操作流程,如市電切換、負(fù)載管理、電池充電/放電管理、故障處理及預(yù)防性維護(hù)項(xiàng)目,以延長(zhǎng)UPS的使用壽命并保證電力供應(yīng)質(zhì)量。
5. 常見(jiàn)問(wèn)題解答與解決方法:針對(duì)可能出現(xiàn)的問(wèn)題提供針對(duì)性的解答,幫助您快速識(shí)別和排除使用過(guò)程中的常見(jiàn)問(wèn)題。
6. 故障代碼列表及解釋:列出UPS可能出現(xiàn)的錯(cuò)誤代碼及其含義,便于您理解和處理設(shè)備報(bào)錯(cuò)情況。
為了獲得最佳效果,請(qǐng)?jiān)陂_(kāi)始使用EA99系列UPS之前仔細(xì)閱讀并按照操作手冊(cè)的指引執(zhí)行相關(guān)步驟。如有任何疑問(wèn)或需要技術(shù)支持,請(qǐng)隨時(shí)聯(lián)系我們的客戶服務(wù)團(tuán)隊(duì)。祝您使用愉快!