XX 熱電聯(lián)產(chǎn)新建工程項(xiàng)目高壓廠用電抗器技術(shù)規(guī)范書
聲明:您必須遵守我們的協(xié)議,如果您下載了該資源行為將被視為對《電天下賬號(hào)管理規(guī)范》全部內(nèi)容的認(rèn)可,本網(wǎng)站資源來自原創(chuàng),僅供用于學(xué)習(xí)和交流,請勿用于商業(yè)用途。如有侵權(quán)、不妥之處,請舉報(bào)本資源,我們將及時(shí)審核處理!
XX 熱電聯(lián)產(chǎn)新建工程項(xiàng)目高壓廠用電抗器技術(shù)規(guī)范書
XX 熱電聯(lián)產(chǎn)新建工程項(xiàng)目高壓廠用電抗器技術(shù)規(guī)范書
文本預(yù)覽
XX 熱電聯(lián)產(chǎn)
新 建 工 程項(xiàng) 目
高壓廠用電抗器
技 術(shù) 規(guī) 范 書
編制:XX 電力工程公司
XXXX 年 X 月XX 熱電聯(lián)產(chǎn)
新 建工程 項(xiàng) 目
高壓廠用電抗器
技 術(shù) 規(guī) 范 書
批 準(zhǔn):
審 核:
編 制:目 錄
1 技術(shù)規(guī)范 ······················································································ 1
1.1 總則 ····················································································· 1
1.2 工程概況··············································································· 1
1.3 設(shè)計(jì)和運(yùn)行條件 ····································································· 2
1.4 技術(shù)參數(shù)和性能要求 ······························································· 4
2 供貨范圍 ······················································································ 5
2.1 一般要求··············································································· 5
2.2 供貨范圍··············································································· 6
3 技術(shù)資料和交付進(jìn)度 ······································································· 8
3.1 一般要求··············································································· 8
3.2 技術(shù)資料清單、進(jìn)度和數(shù)量 ······················································ 8
4 交貨進(jìn)度 ······················································································ 9
4.1 交貨進(jìn)度說明 ········································································ 9
4.2 交貨進(jìn)度清單 ········································································ 9
5 設(shè)備監(jiān)造(檢驗(yàn))和性能驗(yàn)收試驗(yàn) ····················································· 9
5.1 概述 ····················································································· 9
5.2 工廠檢驗(yàn)··············································································· 9
5.3 性能驗(yàn)收試驗(yàn) ······································································· 10
6 價(jià)格表 ························································································ 11
7 技術(shù)服務(wù)和設(shè)計(jì)聯(lián)絡(luò) ······································································ 11
7.1 供方現(xiàn)場技術(shù)服務(wù) ································································· 11
7.2 培訓(xùn) ···················································································· 13
7.3 設(shè)計(jì)聯(lián)絡(luò)·············································································· 14
8 分包商/外購部件情況 ····································································· 14
9 大(部)件情況 ············································································ 15
10 差異表 ························································································ 15XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
1 技術(shù)規(guī)范
1.1 總則
1.1.1 本設(shè)備技術(shù)規(guī)范書適用于XX熱電聯(lián)產(chǎn)新建工程(1×50MW 機(jī)組)2臺(tái)
高壓廠用電抗器,它提出了該設(shè)備的功能設(shè)計(jì)、結(jié)構(gòu)、性能、安裝和試
驗(yàn)等方面的技術(shù)要求。
1.1.2 設(shè)備的供方應(yīng)已取得 ISO9001質(zhì)量體系的有效證書,生產(chǎn)過或合作生產(chǎn)
過3套或以上同類額定值的設(shè)備,該設(shè)備應(yīng)在與本規(guī)范書中規(guī)定條件相
同或較規(guī)定條件更為嚴(yán)格的條件下成功的商業(yè)運(yùn)行三年以上。
1.1.3 本技術(shù)規(guī)范書所提及的要求和供貨范圍都是最低限度的要求,并未對一
切技術(shù)細(xì)節(jié)作出規(guī)定,也未充分地詳述有關(guān)標(biāo)準(zhǔn)和規(guī)范的條文,供方應(yīng)
保證提供符合本技術(shù)規(guī)范書和工業(yè)標(biāo)準(zhǔn)的功能齊全的優(yōu)質(zhì)產(chǎn)品及其相
應(yīng)服務(wù)。對國家有關(guān)安全、環(huán)保等強(qiáng)制性標(biāo)準(zhǔn),必須滿足其要求。
1.1.4 供方應(yīng)仔細(xì)閱讀包括本技術(shù)規(guī)范書在內(nèi)的所有招標(biāo)文件中闡述的全部
條款。如果供方?jīng)]有以書面形式對本規(guī)范書的條文提出異議,則意味著
供方提供的設(shè)備(或系統(tǒng))完全符合本規(guī)范書的要求。如有異議,不管
是多么微小,都應(yīng)在報(bào)價(jià)書中以“對規(guī)范書的意見和同規(guī)范書的差異”
為標(biāo)題的專門章節(jié)中加以詳細(xì)描述。
1.1.5 供方須執(zhí)行本技術(shù)規(guī)范書所列標(biāo)準(zhǔn)。當(dāng)標(biāo)準(zhǔn)之間要求不一致時(shí),應(yīng)按要
求高的技術(shù)條款的標(biāo)準(zhǔn)執(zhí)行。
1.1.6 若供方所提供的技術(shù)規(guī)范書前后有不一致的地方,應(yīng)以更有利于設(shè)備安
裝運(yùn)行、工程質(zhì)量為原則,由需方確定。
1.1.7 在合同簽定后,需方有權(quán)因規(guī)范、標(biāo)準(zhǔn)、規(guī)程發(fā)生變化而提出一些補(bǔ)充
要求,在設(shè)備投料生產(chǎn)前,供方將在設(shè)計(jì)上給以修改。
1.1.8 本設(shè)備技術(shù)規(guī)范書經(jīng)供、需雙方確認(rèn)后作為訂貨合同的技術(shù)附件,與合
同正文具有同等的法律效力。
1.1.9 本設(shè)備技術(shù)規(guī)范書未盡事宜,由供需雙方通過談判商定。
1.2 工程概況
XX熱電聯(lián)產(chǎn)項(xiàng)目廠址地處XX區(qū)XX街道,位于XX區(qū)東南部,距XX城20
公里,距離XX市120 公里。XX街道是XX 區(qū)唯一的移民異地搬遷集鎮(zhèn)和XX區(qū)
XXXX電力工程有限公司 1XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
重點(diǎn)建設(shè)的四個(gè)中心城鎮(zhèn)、XX市重點(diǎn)建設(shè)的 45個(gè)中心鎮(zhèn)、103個(gè)經(jīng)濟(jì)強(qiáng)鎮(zhèn)之一。
全鎮(zhèn)幅員面積 121.5 平方公里,轄 7 個(gè)行政村,59 個(gè)村民小組,一個(gè)社區(qū),3 個(gè)居
民小組,總?cè)丝?1638人。耕地面積45821.1畝,森林面積93438畝,森林覆蓋率
46.8%。
鐵路橫貫全鎮(zhèn),交通、區(qū)位優(yōu)勢明顯。
所址位于XX。交通運(yùn)輸條件十分方便。
1.3 設(shè)計(jì)和運(yùn)行條件
1.3.1 水文氣象
本期項(xiàng)目地處XX市XX區(qū)內(nèi),XX區(qū)屬中亞熱帶濕潤季風(fēng)氣候,其總的特點(diǎn)
是:四季分明,熱量充足,降水豐沛,季風(fēng)影響突出;地勢由西北向東南升高,
氣溫遞降,降水遞增,立體氣候明顯。四季特點(diǎn)為春早,常有“倒春寒”和局部的風(fēng)
雹災(zāi)害;夏長,炎熱,旱澇交錯(cuò),伏旱頻繁;秋短,涼爽而多綿雨;冬遲,無嚴(yán)
寒,雨雪少,常有冬干。氣象資料
1.3.1.1 氣溫
年平均氣溫 18.4 ℃
最熱月平均氣溫 28.2 ℃
最冷月平均氣溫 5.6 ℃
極端最高氣溫 43 ℃
極端最低氣溫 -3.1 ℃
1.3.1.2 降雨、降雪量
歷年平均降雨量 1087.3mm
最大年降雨量 1145mm
最大月降雨量 235.5mm
最大積雪厚度 3cm
1.3.1.3 濕度
歷年平均相對濕度 79.0%
最熱月平均相對濕度 82%
最冷月平均相對濕度 75%
1.3.1.4 歷年平均氣壓 98.39kPa
XXXX電力工程有限公司 2XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
1.3.1.5 特殊氣象
常年平均霧日 68.3d
新 建 工 程項(xiàng) 目
高壓廠用電抗器
技 術(shù) 規(guī) 范 書
編制:XX 電力工程公司
XXXX 年 X 月XX 熱電聯(lián)產(chǎn)
新 建工程 項(xiàng) 目
高壓廠用電抗器
技 術(shù) 規(guī) 范 書
批 準(zhǔn):
審 核:
編 制:目 錄
1 技術(shù)規(guī)范 ······················································································ 1
1.1 總則 ····················································································· 1
1.2 工程概況··············································································· 1
1.3 設(shè)計(jì)和運(yùn)行條件 ····································································· 2
1.4 技術(shù)參數(shù)和性能要求 ······························································· 4
2 供貨范圍 ······················································································ 5
2.1 一般要求··············································································· 5
2.2 供貨范圍··············································································· 6
3 技術(shù)資料和交付進(jìn)度 ······································································· 8
3.1 一般要求··············································································· 8
3.2 技術(shù)資料清單、進(jìn)度和數(shù)量 ······················································ 8
4 交貨進(jìn)度 ······················································································ 9
4.1 交貨進(jìn)度說明 ········································································ 9
4.2 交貨進(jìn)度清單 ········································································ 9
5 設(shè)備監(jiān)造(檢驗(yàn))和性能驗(yàn)收試驗(yàn) ····················································· 9
5.1 概述 ····················································································· 9
5.2 工廠檢驗(yàn)··············································································· 9
5.3 性能驗(yàn)收試驗(yàn) ······································································· 10
6 價(jià)格表 ························································································ 11
7 技術(shù)服務(wù)和設(shè)計(jì)聯(lián)絡(luò) ······································································ 11
7.1 供方現(xiàn)場技術(shù)服務(wù) ································································· 11
7.2 培訓(xùn) ···················································································· 13
7.3 設(shè)計(jì)聯(lián)絡(luò)·············································································· 14
8 分包商/外購部件情況 ····································································· 14
9 大(部)件情況 ············································································ 15
10 差異表 ························································································ 15XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
1 技術(shù)規(guī)范
1.1 總則
1.1.1 本設(shè)備技術(shù)規(guī)范書適用于XX熱電聯(lián)產(chǎn)新建工程(1×50MW 機(jī)組)2臺(tái)
高壓廠用電抗器,它提出了該設(shè)備的功能設(shè)計(jì)、結(jié)構(gòu)、性能、安裝和試
驗(yàn)等方面的技術(shù)要求。
1.1.2 設(shè)備的供方應(yīng)已取得 ISO9001質(zhì)量體系的有效證書,生產(chǎn)過或合作生產(chǎn)
過3套或以上同類額定值的設(shè)備,該設(shè)備應(yīng)在與本規(guī)范書中規(guī)定條件相
同或較規(guī)定條件更為嚴(yán)格的條件下成功的商業(yè)運(yùn)行三年以上。
1.1.3 本技術(shù)規(guī)范書所提及的要求和供貨范圍都是最低限度的要求,并未對一
切技術(shù)細(xì)節(jié)作出規(guī)定,也未充分地詳述有關(guān)標(biāo)準(zhǔn)和規(guī)范的條文,供方應(yīng)
保證提供符合本技術(shù)規(guī)范書和工業(yè)標(biāo)準(zhǔn)的功能齊全的優(yōu)質(zhì)產(chǎn)品及其相
應(yīng)服務(wù)。對國家有關(guān)安全、環(huán)保等強(qiáng)制性標(biāo)準(zhǔn),必須滿足其要求。
1.1.4 供方應(yīng)仔細(xì)閱讀包括本技術(shù)規(guī)范書在內(nèi)的所有招標(biāo)文件中闡述的全部
條款。如果供方?jīng)]有以書面形式對本規(guī)范書的條文提出異議,則意味著
供方提供的設(shè)備(或系統(tǒng))完全符合本規(guī)范書的要求。如有異議,不管
是多么微小,都應(yīng)在報(bào)價(jià)書中以“對規(guī)范書的意見和同規(guī)范書的差異”
為標(biāo)題的專門章節(jié)中加以詳細(xì)描述。
1.1.5 供方須執(zhí)行本技術(shù)規(guī)范書所列標(biāo)準(zhǔn)。當(dāng)標(biāo)準(zhǔn)之間要求不一致時(shí),應(yīng)按要
求高的技術(shù)條款的標(biāo)準(zhǔn)執(zhí)行。
1.1.6 若供方所提供的技術(shù)規(guī)范書前后有不一致的地方,應(yīng)以更有利于設(shè)備安
裝運(yùn)行、工程質(zhì)量為原則,由需方確定。
1.1.7 在合同簽定后,需方有權(quán)因規(guī)范、標(biāo)準(zhǔn)、規(guī)程發(fā)生變化而提出一些補(bǔ)充
要求,在設(shè)備投料生產(chǎn)前,供方將在設(shè)計(jì)上給以修改。
1.1.8 本設(shè)備技術(shù)規(guī)范書經(jīng)供、需雙方確認(rèn)后作為訂貨合同的技術(shù)附件,與合
同正文具有同等的法律效力。
1.1.9 本設(shè)備技術(shù)規(guī)范書未盡事宜,由供需雙方通過談判商定。
1.2 工程概況
XX熱電聯(lián)產(chǎn)項(xiàng)目廠址地處XX區(qū)XX街道,位于XX區(qū)東南部,距XX城20
公里,距離XX市120 公里。XX街道是XX 區(qū)唯一的移民異地搬遷集鎮(zhèn)和XX區(qū)
XXXX電力工程有限公司 1XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
重點(diǎn)建設(shè)的四個(gè)中心城鎮(zhèn)、XX市重點(diǎn)建設(shè)的 45個(gè)中心鎮(zhèn)、103個(gè)經(jīng)濟(jì)強(qiáng)鎮(zhèn)之一。
全鎮(zhèn)幅員面積 121.5 平方公里,轄 7 個(gè)行政村,59 個(gè)村民小組,一個(gè)社區(qū),3 個(gè)居
民小組,總?cè)丝?1638人。耕地面積45821.1畝,森林面積93438畝,森林覆蓋率
46.8%。
鐵路橫貫全鎮(zhèn),交通、區(qū)位優(yōu)勢明顯。
所址位于XX。交通運(yùn)輸條件十分方便。
1.3 設(shè)計(jì)和運(yùn)行條件
1.3.1 水文氣象
本期項(xiàng)目地處XX市XX區(qū)內(nèi),XX區(qū)屬中亞熱帶濕潤季風(fēng)氣候,其總的特點(diǎn)
是:四季分明,熱量充足,降水豐沛,季風(fēng)影響突出;地勢由西北向東南升高,
氣溫遞降,降水遞增,立體氣候明顯。四季特點(diǎn)為春早,常有“倒春寒”和局部的風(fēng)
雹災(zāi)害;夏長,炎熱,旱澇交錯(cuò),伏旱頻繁;秋短,涼爽而多綿雨;冬遲,無嚴(yán)
寒,雨雪少,常有冬干。氣象資料
1.3.1.1 氣溫
年平均氣溫 18.4 ℃
最熱月平均氣溫 28.2 ℃
最冷月平均氣溫 5.6 ℃
極端最高氣溫 43 ℃
極端最低氣溫 -3.1 ℃
1.3.1.2 降雨、降雪量
歷年平均降雨量 1087.3mm
最大年降雨量 1145mm
最大月降雨量 235.5mm
最大積雪厚度 3cm
1.3.1.3 濕度
歷年平均相對濕度 79.0%
最熱月平均相對濕度 82%
最冷月平均相對濕度 75%
1.3.1.4 歷年平均氣壓 98.39kPa
XXXX電力工程有限公司 2XX熱電聯(lián)產(chǎn)新建工程項(xiàng)目 技術(shù)規(guī)范書
1.3.1.5 特殊氣象
常年平均霧日 68.3d